Canon E5877J-P1AK X-ray Image Intensifier
As a high-performance industrial imaging device, the X-ray Image Intensifier E5877J-P1AK is engineered to deliver sharp, detailed X-ray visuals. Boasting exceptional resolution and effective soft X-ray penetration capabilities, it serves as an optimal choice for non-destructive testing scenarios across sectors like electronics, automotive manufacturing, and aerospace engineering. With its lightweight and compact design, this intensifier boosts imaging efficiency and accuracy, guaranteeing consistent, trustworthy outcomes.
Key Features
- Achieves very high resolution up to 110 Lp/cm in M mode for detailed imaging
- Compact design with an overall length of 226 mm and a maximum diameter of 164 mm
- Lightweight, weighing approximately 8.0 kg for easy integration and handling
- CsI direct deposit input screen reduces X-ray scatter and improves detection efficiency
- Anti-reflective coating on the output screen enhances image quality
- Dual operation modes (N mode and M mode) for versatile imaging needs
- Fast setup with a preheat time of less than 3 minutes
- Compliance with international safety standards for reliable and safe operation
Technical Specifications
Mechanical Specifications
| Overall Length | 226±3 mm |
| Maximum Diameter | 164±3 mm |
| Nominal Entrance Field Size | typ. 100 mm |
| Output Image Diameter | 20±1 mm |
| Weight | approx. 8.0 kg |
Electrical Specifications
| Anode Voltage | 25 to 30 kV (N mode), 25 to 30 kV (M mode) |
| G3 Electrode Voltage | 1.5 to 3.5 kV (N mode), 9.0 to 12.0 kV (M mode) |
| G2 Electrode Voltage | 350 to 750 V (N mode), 150 to 550 V (M mode) |
| G1 Electrode Voltage | 50 to 250 V (N mode), 150 to 350 V (M mode) |
| Photocathode Voltage | 0 V |
Power Supply Specifications
| DC Power Supply Input Voltage | 100 to 240 Vac 30VA |
| DC Power Supply Output Voltage | 24±1 Vdc |
| DC Power Supply Output Current | 400 mA max. |
| Weight | approx. 1 kg |
Environmental Specifications
| Operating Temperature | 5°C to 40°C |
| Storage Temperature | -15°C to 45°C |
| Operating Humidity | 30% to 85% RH (non-condensing) |
| Storage Humidity | 10% to 90% RH (non-condensing) |
| Operating Pressure | 70 to 106 kPa |
| Storage Pressure | 50 to 106 kPa |
Performance Specifications
| Central Resolution | 77 Lp/cm (N mode), 110 Lp/cm (M mode) |
| Conversion Factor (Gx) | 90 cd/m2 (typ.) for 10 μGy/s (N mode), 90 cd/m2 (typ.) for 1 mR/s (M mode) |
| Contrast Ratio | 22:1 (10% area) (N mode) |
Safety and Handling Specifications
| Maximum Fluoroscopic X-ray Tube Voltage | 125 kVp |
| Maximum Input Dose Rate | Continuous 4.37*10^-4 Gy/min [50 mR/min], Pulsed 8.73*10^-3 Gy/min [1 R/min] |
| Minimum Distance Between Focal Spot and Entrance Plane | 73 cm |