Canon E5877J-P1K X-ray Image Intensifier for Industrial Inspection
The X-ray Image Intensifier E5877J-P1K is a high-performance industrial imaging solution designed to provide clear and detailed X-ray images. It features very high resolution and efficient soft X-ray penetration, making it ideal for non-destructive inspection applications in industries such as electronics, automotive, and aerospace. This lightweight and compact device enhances imaging efficiency and precision, ensuring reliable and accurate results.
Key Features:
- Achieves very high resolution up to 110 Lp/cm in M mode for detailed imaging.
- Compact design with an overall length of 226 mm and a maximum diameter of 164 mm.
- Lightweight, weighing approximately 8.0 kg for easy integration and handling.
- CsI direct deposit input screen reduces X-ray scatter and improves detection efficiency.
- Anti-reflective coating on the output screen enhances image quality.
- Dual operation modes (N mode and M mode) for versatile imaging needs.
- Fast setup with a preheat time of less than 3 minutes.
- Compliance with international safety standards for reliable and safe operation.
Technical Specifications
Mechanical Specifications:
| Overall Length | 226±3 mm |
| Maximum Diameter | 164±3 mm |
| Nominal Entrance Field Size | typ. 100 mm |
| Output Image Diameter | 20±1 mm |
| Weight | approx. 8.0 kg |
Electrical Specifications:
| Anode Voltage | 25 to 30 kV (N mode), 25 to 30 kV (M mode) |
| G3 Electrode Voltage | 1.5 to 3.5 kV (N mode), 9.0 to 12.0 kV (M mode) |
| G2 Electrode Voltage | 350 to 750 V (N mode), 150 to 550 V (M mode) |
| G1 Electrode Voltage | 50 to 250 V (N mode), 150 to 350 V (M mode) |
| Photocathode Voltage | 0 V |
Power Supply Specifications:
| DC Power Supply Input Voltage | 100 to 240 Vac 30VA |
| DC Power Supply Output Voltage | 24±1 Vdc |
| DC Power Supply Output Current | 400 mA max. |
| Weight | approx. 1 kg |
Environmental Specifications:
| Operating Temperature | 5°C to 40°C |
| Storage Temperature | -15°C to 45°C |
| Operating Humidity | 30% to 85% RH (non-condensing) |
| Storage Humidity | 10% to 90% RH (non-condensing) |
| Operating Pressure | 70 to 106 kPa |
| Storage Pressure | 50 to 106 kPa |
Performance Specifications:
| Central Resolution | 77 Lp/cm (N mode), 110 Lp/cm (M mode) |
| Conversion Factor (Gx) | 90 cd/m2 (typ.) for 10 μGy/s (N mode), 90 cd/m2 (typ.) for 1 mR/s (M mode) |
| Contrast Ratio | 22:1 (10% area) (N mode) |
Safety and Handling Specifications:
| Maximum Fluoroscopic X-ray Tube Voltage | 125 kVp |
| Maximum Input Dose Rate | Continuous 4.37*10^-4 Gy/min [50 mR/min], Pulsed 8.73*10^-3 Gy/min [1 R/min] |
| Minimum Distance Between Focal Spot and Entrance Plane | 73 cm |